Bollard Installers

Tyne and Wear · England

Shallow-mount security bollard installation in Felling

Planning shallow-mount bollards in Felling? We check ownership, consents and buried services first, then quote a fixed price.

Line of dark grey security bollards on a pedestrianised high street with stone paving and a utility access cover beside themComputer-generated image

About shallow-mount bollards in Felling

Across Felling, typical sites for shallow-mount bollards include filling-station forecourts, small industrial units and town-centre squares. Rated shallow-foundation bollard systems installed where buried services, basements or slabs rule out deep excavation.

We cover Felling's NE10 postcode district, including places such as Follingsby. Jobs in Felling can be combined with work in Gateshead (1.4 miles), Newcastle upon Tyne (2.2 miles), Hebburn (2.6 miles) and Wallsend (3 miles) (straight-line distances).

Key facts for this area

Area
Tyne and Wear, England
Highway authority
Gateshead Council (local roads)
Planning authority
Gateshead Council
Postcodes
NE10
Guide price
Typically £1,895–£8,645 per bollard + VAT; minimum job £4,795
Survey
Free, with a fixed written quote
Nearby
Gateshead (1.4 mi), Newcastle upon Tyne (2.2 mi), Hebburn (2.6 mi), Wallsend (3 mi)

Shallow-mount bollards in Felling: common uses

Common uses in a place like Felling:

  • Podium decks, car park roofs and basement slabs
  • Listed or historic streets where deep digging is unwelcome
  • Footways with dense utility runs just below the surface

What shallow-mount bollards cost in Felling

SpecificationGuide priceIncludes
Standard£1,895–£4,745 + VATRated for a 7.5 t vehicle at 30 mph (48 km/h), tested foundation
Upgraded£3,945–£6,745 + VATRated for 7.5 t at 40 mph (64 km/h), tested foundation
Premium£5,945–£8,645 + VATRated for 7.5 t at 50 mph (80 km/h), or a specialist foundation

Per bollard position, supplied and installed; -4% for North East. Guide only — the fixed price follows a survey.

Permissions and groundwork in Felling

Gateshead Council is the highway authority covering Felling's local roads. If any post would stand on adopted highway rather than your land, that consent is the first thing we sort out.

Bollards on private land often don't need planning permission, but it depends on the council's view, the height and the location; in a conservation area, next to a listed building or under an Article 4 direction, ask the local planning authority (Gateshead Council) first — we flag this at survey.

On decks and roofs, the waterproofing and drainage layers must be protected or rebuilt, and fixings must not puncture membranes unless the structural and waterproofing designers have agreed a detail. The trench has to sit over services with enough cover to protect them, but the frame also needs a firm, consistent bearing; soft spots, old backfill around pipe trenches and voids under paving can all need treating first.

  • Record the frame's position on as-built drawings so future excavation near the line can be planned safely.
  • Keep the test certificate for the exact system and configuration, including the minimum run length and end details.

Installation, step by step

Confirm the system with the manufacturer

The survey findings go back to the manufacturer and the client's adviser to confirm the system, its layout and any end details. A fixed written quote follows the free site survey.

Cut and excavate the trench

Paving is lifted and kept for reuse where possible, and a shallow trench is excavated by hand near known services. Where a service sits higher than expected, work stops and the detail is referred back.

Record and hand over

As-built drawings show the frame position relative to services, which matters for anyone digging nearby later. Product certificates and photographs go to the client's adviser.

Options to consider

OptionDetail
Covers and sleevesStainless, cast or powder-coated covers fitted over the cores to match surrounding street furniture, supplied or approved by the manufacturer.
Linked-frame systemsPosts are welded or bolted to a continuous steel frame laid in a shallow trench and encased in concrete. Suited to straight or gently curved lines.
Surface-mounted rated unitsSome tested products sit on or very close to the surface with minimal digging. These are often used for temporary or semi-permanent protection and need careful checking of the surface they bear on.

What affects the quote

When we price shallow-mount bollards in Felling, these make the biggest difference:

  • Changes of direction, end details and removable positions
  • Structural engineering checks on slabs or decks
  • Length of run and the system needed to achieve the rating

Keeping them working

Any later utility work beside the line should be supervised so the frame is not undermined. If one post is struck, the frame may have transmitted load to its neighbours, so the whole run near the impact should be checked with the manufacturer rather than replacing a single post in isolation.

For damaged or loose posts in Felling, repairs and replacements are priced in writing first.

Common questions

Can you install shallow-mount bollards anywhere in Felling?

We cover all of Felling (NE10) and the rest of Tyne and Wear. We also work in Gateshead, Newcastle upon Tyne and Hebburn.

Do I need consent for shallow-mount bollards on a public footway in Felling?

In Felling, work on adopted pavements and verges needs consent from Gateshead Council, the local highway authority. Car parks, forecourts and other private land only need the owner's permission.

What's a typical price for shallow-mount bollards in Felling?

In Felling, typically £1,895–£8,645 per bollard position, supplied and installed, plus VAT, with a minimum job of £4,795 plus VAT, using our North East guide prices. The fixed figure comes in writing after we've seen the site.

How much shallower is a shallow-mount bollard foundation?

Often a fraction of the depth of a conventional rated foundation, commonly a few hundred millimetres. The exact depth depends on the system and rating chosen. What you gain in depth is usually traded for width, because the load is spread along a linked frame.

Does a shallow system protect as well as a deep one?

It can achieve the same rating, because both are tested to the same standards. What differs is how the load is resisted. Your security adviser should compare the specific ratings, not the foundation depths.

Shallow-mount bollards in nearby towns

More from us in Felling

Need bollards fitted?

Free site survey and a fixed, itemised written quote for installation work. Repairs and servicing are priced in writing before we start.

CallFree quote